This method is for the collection and analysis of elements (metals). The sample is collected on a 0.8 micron cellulose ester membrane or 5 micron PVC (polyvinyl chloride) membrane filter. The filter is digested using HNO3/HClO4, and after digestion the sample is analyzed using ICP (inductively coupled plasma).
The working range of this method is 0.005 to 2.0 mg/m³ for each element in a 500L air sample.
NOTE: This method replaces Method P&CAM 351 for trace elements.
No Obligation Quotation for Analytical Services
If you would like us to provide a quote for laboratory analysis, just provide us with as much information as you can about your project (the more, the better) and we'll provide you a quote via email. As you are searching or browsing our Analytical Guide, you'll see the Request-A-Quote icon... just click on it to start the request process.
Hold Times, Preservatives, Preps, Collection, Analytical & Documentation | |
---|---|
Holding Time: | None specified in the method. |
Preservatives: | None specified in the method. |
Required Preps: | 37mm cellulose ester or PVC membrane filter |
Collection Method: | The method recommends a 1 - 4 L/min. with a 5 - 2000L sample collection volume. |
Analytical Methodology: | ICP |
Documentation: | 7300 |
Analyte | Formula | CAS Number | Detection Limit | |
---|---|---|---|---|
Tellurium | Te |
13494-80-9 |
1 |
µg |
Aluminum | Al |
7429-90-5 |
1 |
µg |
Iron | Fe |
7439-89-6 |
1 |
µg |
Lanthanum | La |
7439-91-0 |
1 |
µg |
Lead | Pb |
7439-92-1 |
1 |
µg |
Lithium | Li |
7439-93-2 |
1 |
µg |
Magnesium | Mg |
7439-95-4 |
1 |
µg |
Manganese | Mn |
7439-96-5 |
1 |
µg |
Molybdenum | Mo |
7439-98-7 |
1 |
µg |
Nickel | Ni |
7440-02-0 |
1 |
µg |
Platinum | Pt |
7440-06-4 |
1 |
µg |
Potassium | K |
7440-09-7 |
1 |
µg |
Silver | Ag |
7440-22-4 |
1 |
µg |
Sodium | Na |
7440-23-5 |
1 |
µg |
Strontium | Sr |
7440-24-6 |
1 |
µg |
Thallium | Tl |
7440-28-0 |
1 |
µg |
Tin | Sn |
7440-31-5 |
1 |
µg |
Titanium | Ti |
7440-32-6 |
1 |
µg |
Tungsten | W |
7440-33-7 |
1 |
µg |
Antimony | Sb |
7440-36-0 |
1 |
µg |
Arsenic | As |
7440-38-2 |
1 |
µg |
Barium | Ba |
7440-39-3 |
1 |
µg |
Beryllium | Be |
7440-41-7 |
1 |
µg |
Cadmium | Cd |
7440-43-9 |
1 |
µg |
Chromium | Cr |
7440-47-3 |
1 |
µg |
Cobalt | Co |
7440-48-4 |
1 |
µg |
Copper | Cu |
7440-50-8 |
1 |
µg |
Vanadium | V |
7440-62-2 |
1 |
µg |
Yttrium | Y |
7440-65-5 |
1 |
µg |
Zinc | Zn |
7440-66-6 |
1 |
µg |
Zirconium | Zr |
7440-67-7 |
1 |
µg |
Calcium | Ca |
7440-70-2 |
1 |
µg |
Phosphorus | P |
7723-14-0 |
1 |
µg |
Selenium | Se |
7782-49-2 |
1 |
µg |
* The analytes and detection limits listed for each method represent the typical detection limits and analytes reported for that particular method. Keep in mind that analyte lists may vary from laboratory to laboratory. Detection limits may also vary from lab to lab and are dependent upon the sample size, matrix, and any interferences that may be present in the sample.