Method 6015

Ammonia


This method is for the collection and analysis of ammonia by visible absorption spectrophotometry.  The sample is collected on a sulfuric acid-treated silica gel tube.  A 0.8µm mixed cellulose ester pre-filter may be used to remove particulate interferences if necessary.  After collection, the sample is extracted in 20ml of deionized water and analyzed by visible absorption spectrophotometry.

The working range of the method is 0.2 to 400 ppm (0.15 to 300 mg/m³) for a 10-L air sample.  This method is based on the sampling procedure of Method S347, the automated analytical procedure of EPA Method 350.1, and Standard Methods 417G.


(NIOSH Issue 1: 15 August 1994)

Request-A-Quote

No Obligation Quotation for Analytical Services

If you would like us to provide a quote for laboratory analysis, just provide us with as much information as you can about your project (the more, the better) and we'll provide you a quote via email. As you are searching or browsing our Analytical Guide, you'll see the Request-A-Quote icon... just click on it to start the request process.
Request-A-Quote

Method Data

Hold Times, Preservatives, Preps, Collection, Analytical & Documentation
Holding Time:   None specified in the method.
Preservatives:   None specified in the method.
Required Preps:   Sulfuric acid treated silica gel tube, 200mg/100mg (SKC 226-10-06)
Collection Method:   The method recommends a 0.1 - 0.2 L/min. flow rate with a 0.1 - 96L sample collection volume.
Analytical Methodology:   Visible absorption spectrophotometry
Documentation:   6015

Analyte List*

Analyte Formula CAS Number Detection Limit
Ammonia
NH3
7664-41-7
0.5
 µg

* The analytes and detection limits listed for each method represent the typical detection limits and analytes reported for that particular method. Keep in mind that analyte lists may vary from laboratory to laboratory. Detection limits may also vary from lab to lab and are dependent upon the sample size, matrix, and any interferences that may be present in the sample.