Method 5009

Benzoyl Peroxide by HPLC


This method is used for the analysis of benzoyl peroxide. The sample is collected on cellulose ester membrane filters, dissolved in ethyl ether, and analyzed by HPLC with a UV detection method. The working range is 2 to 19 mg/m³ for a 90 L air sample. NOTE: This is method S253 in a revised format. A non-specific gravimetric method and a non-specific colorimetric method appear in the criteria document.


(NIOSH Issue 2: 15 August 1994)

Request-A-Quote

No Obligation Quotation for Analytical Services

If you would like us to provide a quote for laboratory analysis, just provide us with as much information as you can about your project (the more, the better) and we'll provide you a quote via email. As you are searching or browsing our Analytical Guide, you'll see the Request-A-Quote icon... just click on it to start the request process.
Request-A-Quote

Method Data

Hold Times, Preservatives, Preps, Collection, Analytical & Documentation
Holding Time:   9% loss from filter after 1 week @ 25°C
Preservatives:   25 °C
Required Preps:   Filter: 37-mm diameter, 0.8µm pore size, cellulose ester membrane.
Collection Method:   Filter; 40 L to 400 L @ 1 - 3 L/min
Analytical Methodology:   HPLC/UV
Documentation:   5009

Analyte List*

Analyte Formula CAS Number Detection Limit
Benzoyl peroxide
C14H10O4
94-36-0
0.01
 mg

* The analytes and detection limits listed for each method represent the typical detection limits and analytes reported for that particular method. Keep in mind that analyte lists may vary from laboratory to laboratory. Detection limits may also vary from lab to lab and are dependent upon the sample size, matrix, and any interferences that may be present in the sample.