This method is for the determination of diazomethane. The sample is collected on octanoic acid-coated XAD-2 resin, desorbed in 1 mL of carbon disulfide and allowed to stand for 15 minutes, and analyzed by GC/FID. The working range is 0.1 to 0.6 ppm (0.2 to 1 mg/m³) diazomethane for a 10 L air sample. NOTE: This method revises Method S137.
No Obligation Quotation for Analytical Services
If you would like us to provide a quote for laboratory analysis, just provide us with as much information as you can about your project (the more, the better) and we'll provide you a quote via email. As you are searching or browsing our Analytical Guide, you'll see the Request-A-Quote icon... just click on it to start the request process.
Hold Times, Preservatives, Preps, Collection, Analytical & Documentation | |
---|---|
Holding Time: | Not noted in method |
Preservatives: | Not noted in method |
Required Preps: | Solid sorbent tubes: XAD-2 resin coated with octanoic acid, 100 mg/50 mg, 7cm x 8mm OD x6mm ID |
Collection Method: | Solid sorbent tubes: 6 - 30 L @ 0.20 L/min. |
Analytical Methodology: | GC/FID |
Documentation: | 2515 |
Analyte | Formula | CAS Number | Detection Limit | |
---|---|---|---|---|
Diazomethane | CH2N2 |
334-88-3 |
1 |
µg |
* The analytes and detection limits listed for each method represent the typical detection limits and analytes reported for that particular method. Keep in mind that analyte lists may vary from laboratory to laboratory. Detection limits may also vary from lab to lab and are dependent upon the sample size, matrix, and any interferences that may be present in the sample.