Method S181

Quinone


This method is for the collection and analysis of quinone from workplace air.  The sample is collected on an XAD-2.  After collection, the sample is desorbed with 20% ethanol in hexane and analyzed by HPLC with UV detection.


(NIOSH)

Request-A-Quote

No Obligation Quotation for Analytical Services

If you would like us to provide a quote for laboratory analysis, just provide us with as much information as you can about your project (the more, the better) and we'll provide you a quote via email. As you are searching or browsing our Analytical Guide, you'll see the Request-A-Quote icon... just click on it to start the request process.
Request-A-Quote

Method Data

Hold Times, Preservatives, Preps, Collection, Analytical & Documentation
Holding Time:   7 days from sample collection to analysis.
Preservatives:   Keep samples refrigerated from sample collection to analysis and minimize exposure to light.
Required Preps:   XAD-2 tube, 50/100mg (SKC 226-30-04)
Collection Method:   The method recommends a 0.01 - 0.2 L/min. flow rate with a 24L sample collection volume.
Analytical Methodology:   HPLC/UV
Documentation:   S181

Analyte List*

Analyte Formula CAS Number Detection Limit
p-Benzoquinone
C6H4O2
106-51-4
0.4
 ng

* The analytes and detection limits listed for each method represent the typical detection limits and analytes reported for that particular method. Keep in mind that analyte lists may vary from laboratory to laboratory. Detection limits may also vary from lab to lab and are dependent upon the sample size, matrix, and any interferences that may be present in the sample.