Method S69

Dipropylene Glycol Methyl Ether


This method is for the collection and analysis of dipropylene glycol methyl ether from workplace air.  The sample is collected on a charcoal tube.  After collection, the sample is desorbed with carbon disulfide and analyzed by GC/FID (flame ionization detector).


(NIOSH)

Request-A-Quote

No Obligation Quotation for Analytical Services

If you would like us to provide a quote for laboratory analysis, just provide us with as much information as you can about your project (the more, the better) and we'll provide you a quote via email. As you are searching or browsing our Analytical Guide, you'll see the Request-A-Quote icon... just click on it to start the request process.
Request-A-Quote

Method Data

Hold Times, Preservatives, Preps, Collection, Analytical & Documentation
Holding Time:   None specified in the method.
Preservatives:   None specified in the method.
Required Preps:   Charcoal tube, 50/100mg (SKC 226-01)
Collection Method:   The method recommends a 0.2 L/min. flow rate and a 3 - 10L sample collection volume.
Analytical Methodology:   GC/FID
Documentation:   S69

Analyte List*

Analyte Formula CAS Number Detection Limit
Dipropylene glycol methyl ether
34590-94-8
1.5
 µg

* The analytes and detection limits listed for each method represent the typical detection limits and analytes reported for that particular method. Keep in mind that analyte lists may vary from laboratory to laboratory. Detection limits may also vary from lab to lab and are dependent upon the sample size, matrix, and any interferences that may be present in the sample.