This method is for the determination of dithiocarbamate pesticides from water and wastewater. The sample is digested with acid and carbon disulfide is evolved from hydrolysis of the dithiocarbamate. The evolved carbon disulfide is measured by a UV-visible spectrophotometer.
The method does not distinguish between the individual dithiocarbamates and are reported as a total.
Do not pre-rinse the sample collection bottle with sample prior to collection.
No Obligation Quotation for Analytical Services
If you would like us to provide a quote for laboratory analysis, just provide us with as much information as you can about your project (the more, the better) and we'll provide you a quote via email. As you are searching or browsing our Analytical Guide, you'll see the Request-A-Quote icon... just click on it to start the request process.
Hold Times, Preservatives, Preps, Collection, Analytical & Documentation | |
---|---|
Holding Time: | 7 days from sample collection to analysis. |
Preservatives: | Ice or refrigerate the sample at 4°C from sample collection to extraction. |
Required Preps: | 1L Glass bottle with a Teflon-lined lid. |
Collection Method: | Grab sampling |
Analytical Methodology: | UV-visible spectrophotometry |
Documentation: | 630 |
Analyte | Formula | CAS Number | Detection Limit | |
---|---|---|---|---|
Zineb | C4H6N2S4Zn |
12122-67-7 |
15 |
μg/L |
Thiram | C6H12N2S4 |
137-26-8 |
15 |
μg/L |
Nabam | C4H6N2Na2S4 |
142-59-6 |
15 |
μg/L |
Ferbam | C9H18FeN3S6 |
14484-64-1 |
15 |
μg/L |
Amoban | C4H14N4S4 |
3566-10-7 |
15 |
μg/L |
Busan 40 | C3H6KNOS2 |
51026-28-9 |
15 |
μg/L |
Busan 85 | C3H7KNS2 |
128-03-0 |
15 |
μg/L |
KN Methyl | C2H4KNS2 |
137-41-7 |
15 |
μg/L |
Mancozeb | C8H12MnN4S8Zn |
8018-01-7 |
15 |
μg/L |
Maneb | C4H6MnN2S4 |
12427-38-1 |
15 |
μg/L |
Metham | C2H4NNaS2 |
137-42-8 |
15 |
μg/L |
Niacide | 8011-66-3 |
15 |
μg/L | |
Polyram | C12H12N6S16Zn |
9006-42-2 |
15 |
μg/L |
Sodium dimethyldithiocarbamate | C3H6NNaS2 |
128-04-1 |
15 |
μg/L |
Ziram | C6H12N2S4Zn |
137-30-4 |
15 |
μg/L |
* The analytes and detection limits listed for each method represent the typical detection limits and analytes reported for that particular method. Keep in mind that analyte lists may vary from laboratory to laboratory. Detection limits may also vary from lab to lab and are dependent upon the sample size, matrix, and any interferences that may be present in the sample.