Method PV2053

Resorcinol


This method is for the collection and analysis of resorcinol from workplace air. The sample is collected on an OVS-7 tube.  After collection, the sample is desorbed with methanol and analyzed by GC/FID (flame ionization detector).

NOTE: This is a partially validated method.


(OSHA)

Request-A-Quote

No Obligation Quotation for Analytical Services

If you would like us to provide a quote for laboratory analysis, just provide us with as much information as you can about your project (the more, the better) and we'll provide you a quote via email. As you are searching or browsing our Analytical Guide, you'll see the Request-A-Quote icon... just click on it to start the request process.
Request-A-Quote

Method Data

Hold Times, Preservatives, Preps, Collection, Analytical & Documentation
Holding Time:   Analyte recoveries were greater than 94% when stored for 14 days at ambient and refrigerated temperatures.
Preservatives:   Store samples at ambient or refrigerated temperatures.
Required Preps:   OVS-7 tube, 100/200mg (SKC 226-57)
Collection Method:   The method recommends a 1.0 L/min. flow rate with a 60L sample collection volume.
Analytical Methodology:   GC/FID
Documentation:   PV2053

Analyte List*

Analyte Formula CAS Number Detection Limit
Resorcinol
C6H6O2
108-46-3
8
 µg

* The analytes and detection limits listed for each method represent the typical detection limits and analytes reported for that particular method. Keep in mind that analyte lists may vary from laboratory to laboratory. Detection limits may also vary from lab to lab and are dependent upon the sample size, matrix, and any interferences that may be present in the sample.