Method D-3682

Standard Test Method for Major and Minor Elements in Combustion Residues from Coal Utilization Processes


This method is for the determination of major and minor elements in combustion residues (ash) from coal utilization processes.  The analysis is for the nine major components of coal which are silicon dioxide, aluminum oxide, ferric oxide, titanium dioxide, phosphorus pentoxide, calcium oxide, magnesium oxide, sodium oxide, and postassium oxide using ICP (inductively coupled plasma).

Knowledge of ash composition is also useful in predicting the behavior of ashes and slags in combustion chambers. Utilization of the ash by-products of coal combustion sometimes depends on the chemical composition of the ash.

Note that the chemical composition of laboratory-prepared coal ash may not exactly represent the composition of mineral matter in the coal or the composition of fly ash and slag resulting from commercial-scale burning of the coal.

 

 


(ASTM)

Request-A-Quote

No Obligation Quotation for Analytical Services

If you would like us to provide a quote for laboratory analysis, just provide us with as much information as you can about your project (the more, the better) and we'll provide you a quote via email. As you are searching or browsing our Analytical Guide, you'll see the Request-A-Quote icon... just click on it to start the request process.
Request-A-Quote

Method Data

Hold Times, Preservatives, Preps, Collection, Analytical & Documentation
Holding Time:   None specified in the method.
Preservatives:   None specified in the method.
Required Preps:   4 or 8oz Polyethylene bottle with Teflon-lined lid.
Collection Method:   Grab sampling
Analytical Methodology:   ICP
Documentation:   D3682

Analyte List*

Analyte Formula CAS Number Detection Limit
Potassium oxide
K2O
12136-45-7
0.1
 %
Calcium oxide
CaO
1305-78-8
0.1
 %
Magnesium oxide
MgO
1309-48-4
0.1
 %
Sodium oxide
Na2O
1313-59-3
0.1
 %
Phosphorus pentoxide
P2O5
1314-56-3
0.1
 %
Iron oxide
Fe2O3
1317-60-8
0.1
 %
Aluminum oxide
Al2O3
1344-28-1
0.1
 %
Titanium dioxide
TiO2
13463-67-7
0.1
 %
Silica (SiO2)
SiO2
7631-86-9
0.1
 %

* The analytes and detection limits listed for each method represent the typical detection limits and analytes reported for that particular method. Keep in mind that analyte lists may vary from laboratory to laboratory. Detection limits may also vary from lab to lab and are dependent upon the sample size, matrix, and any interferences that may be present in the sample.