Method 982.30

Amino Acid Profile


This method is for the determination of amino acid from food and food ingredients.  Three aliquots of the sample are taken and prepared using acid hydrolysis, acid oxidation followed by acid hydrolysis, and alkaline hydrolysis.  All three extracts from the procedures are then analyzed by an amino acid analyzer.  Each hydrolysate is used to determine different amino acids.

The percentage recovery of each amino acid is computed determining the nitrogen content for each amino acid.


(AOAC)

Request-A-Quote

No Obligation Quotation for Analytical Services

If you would like us to provide a quote for laboratory analysis, just provide us with as much information as you can about your project (the more, the better) and we'll provide you a quote via email. As you are searching or browsing our Analytical Guide, you'll see the Request-A-Quote icon... just click on it to start the request process.
Request-A-Quote

Method Data

Hold Times, Preservatives, Preps, Collection, Analytical & Documentation
Holding Time:   None specified in the method.
Preservatives:   None specified in the method.
Required Preps:   None
Collection Method:   Grab sampling
Analytical Methodology:   Amino acid analyzer
Documentation:   982.30

Analyte List*

Analyte Formula CAS Number Detection Limit
Proline
C5H9NO2
147-85-3
0.01
 %
Glycine
C2H5NO2
56-40-6
0.01
 %
Alanine
C3H7NO2
56-41-7
0.01
 %
L-Serine
C3H7NO3
56-45-1
0.01
 %
Aspartic acid
C4H7NO4
56-84-8
0.01
 %
L-Glutamic acid
C5H9NO4
56-86-0
0.01
 %
Lysine
C6H14N2O2
56-87-1
0.01
 %
Tyrosine
C9H11NO3
60-18-4
0.01
 %
Leucine
C6H13NO2
61-90-5
0.01
 %
L-Methionine
C5H11NO2S
63-68-3
0.01
 %
L-Phenylalanine
C9H11NO2
63-91-2
0.01
 %
L-Histidine
C6H9N3O2
71-00-1
0.01
 %
Valine
C5H11NO2
72-18-4
0.01
 %
Threonine
C4H9NO3
72-19-5
0.01
 %
Isoleucine
C6H13NO2
73-32-5
0.01
 %
L-Arginine
C6H14N4O2
74-79-3
0.01
 %
Cystine
C6H12N2O4S2
24645-67-8
0.01
 %

* The analytes and detection limits listed for each method represent the typical detection limits and analytes reported for that particular method. Keep in mind that analyte lists may vary from laboratory to laboratory. Detection limits may also vary from lab to lab and are dependent upon the sample size, matrix, and any interferences that may be present in the sample.