This method is applicable for the determination of emissions of Total Reduced Sulfur Compounds (TRS) from recovery furnaces, lime kilns, and smelt dissolving tanks at kraft pulp mills and fuel gas combustion devices at petroleum refineries. Samples are analyzed using a GC/FPD (flame photometric detector).
Sulfur reacts with metal and can bias results, therefore, all components of the sampling train need to be Teflon or Teflon lined. Components of the sampling train include a probe, filter, and three SO2 scrubbers (impingers) in series. The first two impingers are filled with a citrate buffer and the third left empty the solutions should be replaced after each run. These scrubbers are important as they remove SO2 from the gas. Large amounts of SO2 can interfere with the analysis as SO2 elutes near the target compounds making a chromatographic separation difficult.
The method calls for concurrent collection and analysis meaning the sample gas is passed through the scrubbers and directed onto the GC/FPD for analysis. However for non-compliance work, it is not uncommon for samples to be collected in a canister or Tedlar bag and submitted to a laboratory for analysis. It is recommended that samples collected in a canister or Tedlar bag be analyzed as soon as possible.
No Obligation Quotation for Analytical Services
If you would like us to provide a quote for laboratory analysis, just provide us with as much information as you can about your project (the more, the better) and we'll provide you a quote via email. As you are searching or browsing our Analytical Guide, you'll see the Request-A-Quote icon... just click on it to start the request process.
Hold Times, Preservatives, Preps, Collection, Analytical & Documentation | |
---|---|
Holding Time: | None specified in method. |
Preservatives: | None specified in method. |
Required Preps: | Teflon filter |
Collection Method: | Sampling train following Method 16 procedures. |
Analytical Methodology: | GC/FPD (flame photometric detector) |
Documentation: | 16 |
SKU | Item | Price | |
---|---|---|---|
TB | Sampling Bags: Air Sampling Bags | $ Call for Price |
Analyte | Formula | CAS Number | Detection Limit | |
---|---|---|---|---|
Dimethyl disulfide | C2H6S2 |
624-92-0 |
50 |
ppb |
Methyl mercaptan | CH4S |
74-93-1 |
50 |
ppb |
Dimethyl sulfide | C2H6S |
75-18-3 |
50 |
ppb |
Hydrogen sulfide | H2S |
7783-06-4 |
50 |
ppb |
* The analytes and detection limits listed for each method represent the typical detection limits and analytes reported for that particular method. Keep in mind that analyte lists may vary from laboratory to laboratory. Detection limits may also vary from lab to lab and are dependent upon the sample size, matrix, and any interferences that may be present in the sample.