TO-1 is a procedure for the collection and determination of certain volatile organic compounds which can be captured on Tenax® and determined by thermal desorption GC/MS techniques. Compounds which can be determined by this method are nonpolar organics having boiling points in the approximate range of 80-200°C.
No Obligation Quotation for Analytical Services
If you would like us to provide a quote for laboratory analysis, just provide us with as much information as you can about your project (the more, the better) and we'll provide you a quote via email. As you are searching or browsing our Analytical Guide, you'll see the Request-A-Quote icon... just click on it to start the request process.
Hold Times, Preservatives, Preps, Collection, Analytical & Documentation | |
---|---|
Holding Time: | 2 weeks from collection to analysis |
Preservatives: | Store tubes at -20 °C in a clean freezer, if possible |
Required Preps: | Thermally conditioned Tenax tube with a culture tube or can; Collection within two weeks of preparation |
Collection Method: | TO-1 (with ASTM D3686 for an appropriate calibration scheme) |
Analytical Methodology: | GC/MS (GC/FID is also acceptable) |
Documentation: | TO-1 |
Analyte | Formula | CAS Number | Detection Limit | |
---|---|---|---|---|
Ethylbenzene | C8H10 |
100-41-4 |
10 |
ng |
1,2-Dibromoethane | C2H4Br2 |
106-93-4 |
10 |
ng |
1,2-Dichloroethane | C2H4Cl2 |
107-06-2 |
10 |
ng |
Bromobenzene | C6H5Br |
108-86-1 |
10 |
ng |
Toluene | C7H8 |
108-88-3 |
10 |
ng |
Chlorobenzene | C6H5Cl |
108-90-7 |
10 |
ng |
Tetrachloroethene | C2Cl4 |
127-18-4 |
10 |
ng |
Xylenes (total) | 1330-20-7 |
10 |
ng | |
1,3-Dichloropropane | C3H6Cl2 |
142-28-9 |
10 |
ng |
Heptane | C7H16 |
142-82-5 |
10 |
ng |
Carbon tetrachloride | CCl4 |
56-23-5 |
10 |
ng |
1-Heptene | C7H14 |
592-76-7 |
10 |
ng |
Chloroform | CHCl3 |
67-66-3 |
10 |
ng |
Benzene | C6H6 |
71-43-2 |
10 |
ng |
1,1,1-Trichloroethane | C2H3Cl3 |
71-55-6 |
10 |
ng |
Bromoform | CHBr3 |
75-25-2 |
10 |
ng |
1,2-Dichloropropane | C3H6Cl2 |
78-87-5 |
10 |
ng |
Trichloroethene | C2HCl3 |
79-01-6 |
10 |
ng |
Cumene (Isopropylbenzene) | C9H12 |
98-82-8 |
10 |
ng |
* The analytes and detection limits listed for each method represent the typical detection limits and analytes reported for that particular method. Keep in mind that analyte lists may vary from laboratory to laboratory. Detection limits may also vary from lab to lab and are dependent upon the sample size, matrix, and any interferences that may be present in the sample.