Method 98

Trimellitic anhydride by HPLC-UV


This method describes the sample collection and analysis of trimellitic anhydride. Samples are collected open face on glass fiber filters coated with veratrylamine (3,4-dimethoxybenzylamine) and di-n-octyl phthalate. Samples are extracted with aqueous ammonium hydroxide and analyzed by HPLC using a UV detector.


(OSHA)

Request-A-Quote

No Obligation Quotation for Analytical Services

If you would like us to provide a quote for laboratory analysis, just provide us with as much information as you can about your project (the more, the better) and we'll provide you a quote via email. As you are searching or browsing our Analytical Guide, you'll see the Request-A-Quote icon... just click on it to start the request process.
Request-A-Quote

Method Data

Hold Times, Preservatives, Preps, Collection, Analytical & Documentation
Holding Time:   Up to 16 days.
Preservatives:   Store at room temperature.
Required Preps:   A four-piece polystyrene cassette containing two coated glass fiber filters.
Collection Method:   Glass fiber filters: 480 L at 2.0 L/min.
Analytical Methodology:   HPLC/UV.
Documentation:   098

Analyte List*

Analyte Formula CAS Number Detection Limit
Trimellitic anhydride
C9H4O5
552-30-7
0.106
 µg

* The analytes and detection limits listed for each method represent the typical detection limits and analytes reported for that particular method. Keep in mind that analyte lists may vary from laboratory to laboratory. Detection limits may also vary from lab to lab and are dependent upon the sample size, matrix, and any interferences that may be present in the sample.