Standard Test Method for Heat of Combustion of Liquid Hydrocarbon Fuels by Bomb Calorimeter


This method is for the determination of the heat of combustion of liquid hydrocarbon fuels ranging in volatility from that of light distillates to residual fuels. Under normal conditions the method is applicable to gasolines, kerosines, No. 1 and No. 2 fuel oil, No. 1-D and 2-D diesel fuel, and No. o-Gt, 1-GT, and 2GT gas tubine fuels. An aliquot of the sample is measured by bomb calorimeter.


(ASTM)

Request-A-Quote

No Obligation Quotation for Analytical Services

If you would like us to provide a quote for laboratory analysis, just provide us with as much information as you can about your project (the more, the better) and we'll provide you a quote via email. As you are searching or browsing our Analytical Guide, you'll see the Request-A-Quote icon... just click on it to start the request process.
Request-A-Quote

Method Data

Hold Times, Preservatives, Preps, Collection, Analytical & Documentation
Holding Time:   None specified in the method.
Preservatives:   None specified in the method.
Required Preps:   100mL Glass bottle with Teflon-lined lid
Collection Method:   Grab sampling
Analytical Methodology:   Bomb calorimeter
Documentation:   D-240

Analyte List*

Analyte Formula CAS Number Detection Limit

* The analytes and detection limits listed for each method represent the typical detection limits and analytes reported for that particular method. Keep in mind that analyte lists may vary from laboratory to laboratory. Detection limits may also vary from lab to lab and are dependent upon the sample size, matrix, and any interferences that may be present in the sample.